VSB 40.1 PC Box 7-13
DOK-SUPPL*-VSB*40.1***-PR02-EN-P
This connection is used for device variants for 230/115 VAC.
All internally required voltages are generated by the 230/115 VAC power
supply unit.
CAUTION
The supply voltage must comply with
overvoltage category II! Otherwise the
integrated power supply unit might be
destructed.
⇒ Use an isolating transformer to generate the
230/115 VAC (see following page).
The 230/115 VAC connection occurs via a 3-pin inlet connector for AC
connectors on the connector panel. The maximum cable cross section for
the connected cables is 1.5 mm
2
.
X20
Assignment
PE
N1
U2
PE
230V_Buchse.cdr
Fig. 7-15: Pin assignment of the 230/115 VAC connection X20
Parameters Value
Rated voltage 85 VAC ... 264 VAC auto range
Power consumption for U
N
= 230 VAC 2.5 A
Power consumption for U
N
= 115 VAC 5 A
Inrush current for 264 VAC 100 A
Overload protection As of 135 %, deactivation
Short-circuit protection At all outputs, deactivation
Fig. 7-16: Technical data 115/230 VAC connection
230/115 VAC Power Supply